Investigation Report

Turbine Generator Enclosure Fire on Appomattox Platform

BSEEBureau of Safety and Environmental Enforcement

11-30-2021 19:17 G33733 MC 437 Fire - INCIDENT >$25K 701 generator enclosure - REQUIRED MUSTER

Read at BSEEOpens the document on bsee.gov

Summary

Investigation of a turbine-generator enclosure fire on the Appomattox production platform. Vibration loosened exhaust-hatch fasteners, allowing hot exhaust to ignite plastic sheeting. The report describes shutdown, full muster, firefighting and thermal imaging checks. No injuries, explosions or environmental harm were reported; damage was estimated at $10 million.

Topics

About This Record
Original title
11-30-2021 19:17 G33733 MC 437 Fire - INCIDENT >$25K 701 generator enclosure - REQUIRED MUSTER
Publisher
Bureau of Safety and Environmental Enforcement
Type
Investigation Report
Date
Unknown
Topic
Fire, Mechanical Failure
Equipment
Rotating Machinery
Control
Emergency Response, Fire Protection, Thermography
Sector
Upstream Oil and Gas
Setting
Offshore Installation