Investigation Report

Finger Latch and Retention Cable Fell During Drill-Pipe Racking

BSEEBureau of Safety and Environmental Enforcement

01-23-2022 01:40 G09981 GC 825 Other - Lifting - Dropped object

Read at BSEEOpens the document on bsee.gov

Summary

Investigation of a finger latch and retention cable falling approximately 101 feet during drill-pipe racking on Diamond Offshore Black Lion. No injuries were reported. Findings address inadequate visibility, departure from the site-specific plan, ineffective retention and faulty latch-status data. Subsequent actions included additional retention and trials of alternative latch arrangements.

Topics

About This Record
Original title
01-23-2022 01:40 G09981 GC 825 Other - Lifting - Dropped object
Publisher
Bureau of Safety and Environmental Enforcement
Type
Investigation Report
Date
Unknown
Topic
Dropped Objects, Human Factors, Mechanical Failure
Activity
Drilling, Lifting Operations
Equipment
Operator Displays and Control Interfaces
Control
Exclusion Zones, Operating and Work Procedures, Positive Retention and Reliable Securing
Sector
Upstream Oil and Gas
Link
Checked , working
Record
bsee-8cf24dde8a · added 2 October 2026