Investigation Report
Hydrocarbon Release and Fire Following Compressor Level Test
Read at BSEEOpens the document on bsee.gov
Summary
An offshore compressor level test preceded inadvertent opening of a ball valve, releasing pressurised hydrocarbons through unsecured drain tubing. The tubing struck an operator and the hydrocarbons ignited. The investigation identifies drain-line securing, an uncapped tubing end and valve locking failure, alongside deficient inspection of a wheeled firefighting unit.