Investigation Report

Finger Trapped by Bolt During BOP Installation

BSEEBureau of Safety and Environmental Enforcement

08-22-2013 15:45 G01870 ST 26 Required Evacuation/RW/JT (>3days)/Crane

Read at BSEEOpens the document on bsee.gov

Summary

An investigation examines a finger fracture during BOP installation for well abandonment at ST. 26-D. While the crane lowered the assembly, a misaligned bolt moved upwards and trapped the worker’s finger. The report identifies hazardous hand placement and discusses slippery gloves and simultaneous alignment of twelve bolts as possible contributors.

Topics

About This Record
Original title
08-22-2013 15:45 G01870 ST 26 Required Evacuation/RW/JT (>3days)/Crane
Publisher
Bureau of Safety and Environmental Enforcement
Type
Investigation Report
Date
Unknown
Topic
Crushing and Pinch Points, Hand and Finger Injuries
Activity
Lifting Operations, Well Abandonment
Equipment
Blowout Preventer, Personal Protective Equipment, Wellhead
Control
Job Safety Analysis
Sector
Upstream Oil and Gas