Safety Alert

Motion Compensated Gangways Auto-retraction

HSEUK Health and Safety ExecutiveED03-2025

Motion Compensated Gangways Auto-retraction

Read at HSEOpens the publisher’s page on hse.gov.uk

Summary

HSE warns that power failures or control-system errors can trigger unexpected retraction of motion-compensated gangways, exposing users to falls and moving parts. The notice requires reviews of gangway arrangements, design and automatic-function testing, and calls for adequate advance warnings and rigorous assessment of operator overrides.

Topics

About This Record
Publisher
UK Health and Safety Executive
Type
Safety Alert
Reference
ED03-2025
Date
August 2025
Topic
Falls from Height, Line of Fire
Activity
Personnel Transfer
Equipment
Gangway
Control
Alarm Management, Functional Testing, Risk Assessment, Stop-Work Authority
Sector
Upstream Oil and Gas
Link
Checked , working
Record
hse-ed03-2025 · added 2 September 2026