Safety Alert

Side Door Collar Elevators Drops Casing Joint

IADCInternational Association of Drilling ContractorsIADC Alert 01-04

Side Door Collar Elevators Drops Casing Joint

Read at IADCOpens the publisher’s page on iadc.org

Summary

A casing joint approximately 40 feet long fell through collar elevators as it approached vertical during rig-floor hoisting. Despite insertion of the safety pin, the joint fell, hit the V-door and slid to the catwalk, striking a floorman’s lower back. He was taken to hospital with a back injury.

Topics

About This Record
Publisher
International Association of Drilling Contractors
Type
Safety Alert
Reference
IADC Alert 01-04
Date
9 February 2001
Topic
Dropped Objects, Line of Fire
Activity
Drilling, Lifting Operations, Rigging
Equipment
Lifting Accessories
Sector
Upstream Oil and Gas