Safety Alert

Internal Explosion Ruptures Crown Mounted Compensator Piping

IADCInternational Association of Drilling ContractorsIADC Alert 14-01

Internal Explosion Ruptures Crown Mounted Compensator Piping

Read at IADCOpens the publisher’s page on iadc.org

Summary

An alert describes ignition during pressure equalisation between composite air pressure vessels on a crown mounted compensator. Adiabatic compression heat or air-transfer static was identified as the ignition source. Rising pressure and temperature ruptured connecting pipework, leaving two employees with non-life-threatening injuries requiring shore-based treatment.

Topics

About This Record
Publisher
International Association of Drilling Contractors
Type
Safety Alert
Reference
IADC Alert 14-01
Date
21 January 2014
Topic
Explosion, Mechanical Failure, Pressure Systems, Static Electricity
Equipment
Pressure Vessel, Process Pipework and Pipelines
Sector
Upstream Oil and Gas
Link