Safety Alert

Sheared Wireline Tool Results in Dropped Object

IADCInternational Association of Drilling ContractorsIADC Alert 18-01

Sheared Wireline Tool Results in Dropped Object

Read at IADCOpens the publisher’s page on iadc.org

Summary

During wireline tool assembly, rig heave brought a needle-valve bleed-off manifold on a Coil Tubing Lift Frame into contact with the lifting bridle as a winch lowered the string. The manifold sheared at its threaded coupling and fell 30 ft to the rig floor. It weighed 7 lb; nobody was injured.

Topics

About This Record
Publisher
International Association of Drilling Contractors
Type
Safety Alert
Reference
IADC Alert 18-01
Date
12 January 2018
Topic
Dropped Objects, Mechanical Failure
Activity
Lifting Operations
Equipment
Lifting Accessories, Valve
Sector
Upstream Oil and Gas
Link
Checked , working
Record
iadc-alert-18-01 · added 3 September 2026