Safety Flash

Galvanic corrosion causes dropped object – satellite dome fell from mast

IMCAInternational Marine Contractors AssociationIMCA SF 04/18

Galvanic corrosion causes dropped object – satellite dome fell from mast

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

A vessel’s mast-mounted satellite antenna dome fell during heavy weather, without injuries. Investigation identified galvanic corrosion of mild steel bolts paired with stainless steel nuts, inadequate bolt sizing and difficult inspection access. The flash discusses planned maintenance revisions, compatible mounting materials and consideration of welded attachments where practical.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 04/18
Date
20 February 2018
Topic
Corrosion, Dropped Objects, Structural and Asset Integrity
Activity
Inspection and Maintenance
Control
Positive Retention and Reliable Securing, Preventive Maintenance
Sector
Marine Industry
Setting
Vessel