Safety Flash

Failure of remote control/emergency stop on rescue boat winch

IMCAInternational Marine Contractors AssociationIMCA SF 05/21

Failure of remote control/emergency stop on rescue boat winch

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

During rescue-boat recovery, remote control and emergency-stop functions failed, and the limit switch did not stop retrieval. Inspection found a contactor stuck closed; frequent short switching intervals were considered the most probable cause. The flash emphasises correct retrieval procedures, component inspection and replacement, and regular emergency-stop function testing within planned maintenance.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 05/21
Date
11 February 2021
Topic
Functional Safety, Mechanical Failure
Activity
Inspection and Maintenance, Lifting Operations
Equipment
Operator Displays and Control Interfaces, Rescue-Craft Davit, Winch
Control
Functional Testing, Energy and Process Isolation, Operating and Work Procedures, Preventive Maintenance
Sector
Marine Industry
Setting
Vessel
Link
Checked , working
Record
imca-sf-05-21-failure-of-remote-controlemergency-stop-on-rescue-boat-winch · added 1 September 2026