Investigation Report

Emergency Buoy Disconnect Failed Following Loss of Station

BSEEBureau of Safety and Environmental Enforcement

12-01-2025 1843 G15563 GC 237 Damaged/Disabled Safety System (EDS)

Read at BSEEOpens the document on bsee.gov

Summary

BSEE investigates a failed emergency buoy disconnect on Helix Producer 1 following weather-related loss of station. Subsea production shut in successfully, but a hydraulic piston failed to open. The report details disconnect-system testing, piston replacement and subsequent maintenance measures; teardown inspection found no cylinder failure, and no injuries or infrastructure damage were reported.

Topics

About This Record
Original title
12-01-2025 1843 G15563 GC 237 Damaged/Disabled Safety System (EDS)
Publisher
Bureau of Safety and Environmental Enforcement
Type
Investigation Report
Date
Unknown
Topic
Functional Safety, Loss of Station Keeping, Mechanical Failure
Activity
Dynamic Positioning, Inspection and Maintenance
Equipment
Operator Displays and Control Interfaces
Control
Functional Testing, Independent Audit and Verification, Preventive Maintenance
Sector
Upstream Oil and Gas
Setting
Offshore Installation, Vessel
Link
Checked , working
Record
bsee-15e8bb8406 · added 2 October 2026