A vessel suffered a DP drive-off during open-water valve monitoring after water ingress through a failed junction-box seal led to a wind-sensor wire break. Erroneous wind readings affected positioning; the vessel stabilised 17 m from its set-point. Actions included wiring changes, a discrepancy alarm and fleet-wide wire-break tests.
Classifications: Loss of station keeping; drive-off; drift-off.