Safety Flash

Wire break in wind sensor caused DP drive-off

IMCAInternational Marine Contractors AssociationIMCA SF 12/06

Wire break in wind sensor caused DP drive-off

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

A vessel suffered a DP drive-off during open-water valve monitoring after water ingress through a failed junction-box seal led to a wind-sensor wire break. Erroneous wind readings affected positioning; the vessel stabilised 17 m from its set-point. Actions included wiring changes, a discrepancy alarm and fleet-wide wire-break tests.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 12/06
Date
9 October 2006
Topic
Loss of Station Keeping, Mechanical Failure
Activity
Dynamic Positioning
Equipment
Operator Displays and Control Interfaces
Control
Alarm Management, Functional Testing
Sector
Marine Industry
Setting
Marine Waters, Vessel