Safety Flash

Power management system dynamic positioning (DP) incident

IMCAInternational Marine Contractors AssociationIMCA SF 07/02

Power management system dynamic positioning (DP) incident

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

A power management fault interrupted stern thruster operation during saturation diving, causing a DP vessel to leave its intended position. Divers returned to the bell and were recovered. The flash examines inadequate control-card segregation and an unidentified single-point failure, recommending reconfiguration, electrical protection, independent review and FMEA validation trials.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 07/02
Date
3 July 2002
Topic
Loss of Station Keeping
Activity
Dynamic Positioning, Saturation Diving
Control
Emergency Response, Functional Testing, Independent Audit and Verification
Sector
Marine Industry
Setting
Subsea, Vessel
Link
Checked , working
Record
imca-sf-07-02-power-management-system-dynamic-positioning-dp-incident · added 1 September 2026

Report a problem with this record