Safety Flash

Subsea oxy-arc cutting – risk of explosion

IMCAInternational Marine Contractors AssociationIMCA SF 08/10

Subsea oxy-arc cutting – risk of explosion

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

This safety flash addresses explosion risk during subsea oxy-arc cutting. It recommends dependable double isolation that breaks both circuit poles between the surface generator and diver. Referenced diving guidance advises mounting the knife switch against accidental activation, ideally using a double-pole switch enclosed in a protective wooden or plastic box.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 08/10
Date
15 December 2010
Topic
Electrical Safety, Explosion
Activity
Diving Operations, Hot Work
Equipment
Switchgear
Control
Energy and Process Isolation
Setting
Subsea
Link
Checked , working
Record
imca-sf-08-10-subsea-oxy-arc-cutting-risk-of-explosion · added 1 September 2026

Report a problem with this record