Summary

An oxy-acetylene cutting hose detached during modification work inside a pile-driving hammer, producing a flashback. An improvised taped connection joined mismatched components and slipped off when warmed. The fire watch extinguished the flames; nobody was harmed. Corrective actions included hose inspections, crew training and renewed emphasis on pre-job checks.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 08/14
Date
4 June 2014
Topic
Fire, Mechanical Failure, Pressure Systems
Activity
Hot Work
Equipment
Hose
Control
Competence and Training, Fire Protection, Pre-Use Checks, Safety Communication