Safety Flash

Main bell wire rope damaged

IMCAInternational Marine Contractors AssociationIMCA SF 08/24

Main bell wire rope damaged

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

During bell recovery after a saturation dive, a broken outer wire rope strand lifted a proximity switch bracket into the sheave, damaging the main bell wire. Operators stopped recovery and freed the bracket. The flash describes design shortcomings, sensor relocation, cutting back damaged wire, a witnessed load test and an empty-bell trial.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 08/24
Date
16 April 2024
Topic
Mechanical Failure
Activity
Inspection and Maintenance, Lifting Operations, Saturation Diving
Equipment
Diving Bell, Wire Rope
Control
Functional Testing, Independent Audit and Verification, Stop-Work Authority
Link
Checked , working
Record
imca-sf-08-24-main-bell-wire-rope-damaged · added 1 September 2026