Read at IMCAOpens the publisher’s page on imca-int.com

Summary

This safety flash describes an ROV/TMS and docking head falling from approximately 1 m during launch, following a guide bar falling more than 4 m. Preliminary findings link weld and clevis failures to possible operation with locked damping cylinders. It examines conflicting procedures, design suitability and missed maintenance indications.