Summary
A diving operation was stopped after umbilical distance markings were found to use incorrect colours and a wrong measurement datum. Nobody was harmed, but checking and remarking caused lost time. The flash addresses unclear checking responsibilities, refresher training, mobilisation checks and audit comparison using a 50 m tape.