Safety Flash

Crane wire failure

IMCAInternational Marine Contractors AssociationIMCA SF 10/05

Crane wire failure

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

A crane wire parted during night-time recovery of a work-class ROV onto a survey vessel. The investigation linked prior over-recovery to sheave damage and crushed wire, followed by impact loading through the splash zone. Corrective actions addressed inspection checklists, reporting findings, management of change and risk assessments.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 10/05
Date
31 October 2005
Topic
Mechanical Failure
Activity
Inspection and Maintenance, Lifting Operations, ROV Operations
Equipment
Crane, Wire Rope
Control
Management of Change, Risk Assessment, Safety Communication
Sector
Marine Industry
Setting
Vessel