Safety Flash

Dropped object: Lay tower adjuster leg pin

IMCAInternational Marine Contractors AssociationIMCA SF 11/17

Dropped object: Lay tower adjuster leg pin

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

A 600 kg securing pin fell 16 m to deck after keeper plate bolts loosened; nobody was injured. The flash identifies unclear maintenance and inspection arrangements and possible movement and lubrication issues. Actions included structural NDT, stronger anti-rotation bolts, bolt locking, revised inspection criteria and survival-mode positioning during transits.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 11/17
Date
22 May 2017
Topic
Dropped Objects, Mechanical Failure
Activity
Inspection and Maintenance
Control
Non-Destructive Testing, Operating and Work Procedures, Positive Retention and Reliable Securing, Preventive Maintenance
Sector
Marine Industry
Setting
Vessel
Link
Checked , working
Record
imca-sf-11-17-dropped-object-lay-tower-adjuster-leg-pin · added 1 September 2026

Report a problem with this record