Safety Flash

Near miss: Floor Plate fell from Main Mast during storm

IMCAInternational Marine Contractors AssociationIMCA SF 11/22

Near miss: Floor Plate fell from Main Mast during storm

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

A mast floor plate fell onto a vessel’s deck during storm conditions, without injury or property damage. Its four securing screws had sheared; replacements fitted by a subcontractor were too short and of poor quality. Actions included suitable fixings, checks of similar plates and feedback requiring improved contractor workmanship.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 11/22
Date
4 May 2022
Topic
Dropped Objects, Mechanical Failure
Activity
Inspection and Maintenance
Control
Contractor Management, Positive Retention and Reliable Securing
Sector
Marine Industry
Setting
Vessel
Link
Checked , working
Record
imca-sf-11-22-near-miss-floor-plate-fell-from-main-mast-during-storm · added 1 September 2026