Safety Flash
Regulator fire
Read at IMCAOpens the publisher’s page on imca-int.com
Summary
This reissued safety flash describes two oxygen regulator fires in which pressure was applied with the regulators fully dialled in. Workforce recommendations cover cylinder securing, contamination and damage checks, regulator compatibility, valve opening, pressure adjustment, leak checks and temporary shutdown, including draining the system and releasing adjusting-spring pressure.