Summary

This reissued safety flash describes two oxygen regulator fires in which pressure was applied with the regulators fully dialled in. Workforce recommendations cover cylinder securing, contamination and damage checks, regulator compatibility, valve opening, pressure adjustment, leak checks and temporary shutdown, including draining the system and releasing adjusting-spring pressure.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 12/03
Date
2 September 2003
Topic
Fire, Pressure Systems
Activity
Inspection and Maintenance
Equipment
Gas Cylinder, Valve
Control
Operating and Work Procedures, Positive Retention and Reliable Securing, Pre-Use Checks