Safety Flash

Unapproved repair of diver gas supply umbilical

IMCAInternational Marine Contractors AssociationIMCA SF 12/18

Unapproved repair of diver gas supply umbilical

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

An undocumented gas-hose repair was discovered during demobilisation of a diver umbilical, which was subsequently scrapped. The heat-shrink-covered join could trap seawater and accelerate fitting corrosion, potentially interrupting breathing-gas supply. The member allowed such repairs only temporarily, pending a permanent fix, risk assessment and full management approval.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 12/18
Date
14 June 2018
Topic
Corrosion, Pressure Systems
Activity
Diving Operations, Inspection and Maintenance
Equipment
Diver Umbilical, Hose
Control
Risk Assessment, Safety Communication
Sector
Marine Industry
Link
Checked , working
Record
imca-sf-12-18-unapproved-repair-of-diver-gas-supply-umbilical · added 1 September 2026