Safety Flash
Crane boom stopper fell to main deck
Read at IMCAOpens the publisher’s page on imca-int.com
Summary
A vessel crane’s knuckle boom stopper pad detached during slewing in preparation for use. The 15.5 kg component fell 35 m to the main deck without injuring anyone. The flash describes its adhesive-only attachment, subsequent mechanical securing, and recommendations for additional fixings and inspection of difficult-to-access dropped-object hazards.