Safety Flash

Crane boom stopper fell to main deck

IMCAInternational Marine Contractors AssociationIMCA SF 12/23

Crane boom stopper fell to main deck

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

A vessel crane’s knuckle boom stopper pad detached during slewing in preparation for use. The 15.5 kg component fell 35 m to the main deck without injuring anyone. The flash describes its adhesive-only attachment, subsequent mechanical securing, and recommendations for additional fixings and inspection of difficult-to-access dropped-object hazards.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 12/23
Date
16 May 2023
Topic
Dropped Objects, Mechanical Failure
Activity
Inspection and Maintenance
Equipment
Crane
Control
Positive Retention and Reliable Securing, Preventive Maintenance
Sector
Marine Industry
Setting
Vessel