Safety Flash

Dropped object – Door detached from TMS during dive

IMCAInternational Marine Contractors AssociationIMCA SF 17/21

Dropped object – Door detached from TMS during dive

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

An ROV tether management system lost an aluminium door subsea after both bottom latches failed. The investigation identified an omitted check for secondary retention. The flash recommends checking fixings and reviewing dive checklists; DROPS cone analysis judged damage to nearby subsea assets very unlikely.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 17/21
Date
16 June 2021
Topic
Dropped Objects, Mechanical Failure
Activity
Inspection and Maintenance, ROV Operations
Equipment
Remotely Operated Vehicle
Control
Positive Retention and Reliable Securing, Pre-Use Checks
Sector
Marine Industry
Setting
Subsea
Link
Checked , working
Record
imca-sf-17-21-dropped-object-door-detached-from-tms-during-dive · added 1 September 2026

Report a problem with this record