Summary
A near miss during bell and clump-weight deployment involved a protruding wire strand. Following recovery, inspection identified 60 m of damaged rope for removal and re-termination. Third-party load testing preceded resumed diving. Lessons address visual inspection, defect reporting and limiting rope stress from tidal currents and adverse weather.
Classifications: Mechanical failure; equipment failure.
Classifications: Diving operations; diving; commercial diving.
Classifications: Inspection and maintenance; asset inspection; equipment maintenance.
Classifications: Wire rope; steel wire rope.
Classifications: Functional testing; function test.
Classifications: Marine industry; shipping industry; maritime sector.
Classifications: Vessel; aboard ship; onboard vessel.
Summary
During deployment of the bell and clump weight from a vessel for subsea inspection of a riser line, it was observed that a single wire strand protruded from original lay (‘high stranding’).