Summary
A near miss during onshore blasting and painting involved a 2″ hose separating at an improperly tightened Chicago connector. Its restraint arrested the hose, but released energy overturned an air receiver standing unstably on sand. The flash recommends stable footings, connection inspections, restraints and assessment of safer connectors and protective barriers.
Classifications: Line of fire; struck-by hazards.
Classifications: Mechanical failure; equipment failure.
Classifications: Pressure systems; stored pressure; pressurised systems; pressurized systems.
Classifications: Hose; flexible hose.
Classifications: Pressure vessel; pressure vessels.
Classifications: Exclusion zones; red zones; restricted access zones.
Classifications: Positive retention and reliable securing.
Classifications: Risk assessment; hazard assessment.
Classifications: Onshore facility; onshore plant.
Summary
An improperly secured high-pressure hose separated from an air receiver, releasing stored energy and overturning the unstable vessel.