Safety Flash

Near miss: unplanned release of 2″ blasting hose outlet from air receiver coupling clamp

IMCAInternational Marine Contractors AssociationIMCA SF 18/18

Near miss: unplanned release of 2″ blasting hose outlet from air receiver coupling clamp

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

A near miss during onshore blasting and painting involved a 2″ hose separating at an improperly tightened Chicago connector. Its restraint arrested the hose, but released energy overturned an air receiver standing unstably on sand. The flash recommends stable footings, connection inspections, restraints and assessment of safer connectors and protective barriers.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 18/18
Date
23 August 2018
Topic
Line of Fire, Mechanical Failure, Pressure Systems
Equipment
Hose, Pressure Vessel
Control
Exclusion Zones, Positive Retention and Reliable Securing, Risk Assessment
Setting
Onshore Facility
Link
Checked , working
Record
imca-sf-18-18-near-miss-unplanned-release-of-2-blasting-hose-outlet-from-air-receiver-coupling-clamp · added 1 September 2026

Report a problem with this record