Summary

A new, incorrectly selected pressure gauge leaked steam when its safety seal failed during recommissioning. A lookalike percentage gauge had been retained locally after an ordering error and installed instead of a pressure gauge. Recommendations address stores organisation, returning unused equipment, functional checks before installation and rationalising redundant gauges.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 20/17
Date
11 August 2017
Topic
Loss of Containment, Mechanical Failure, Pressure Systems
Activity
Inspection and Maintenance
Control
Functional Testing, Pre-Use Checks