Safety Flash

High potential incident: gantry hoist failure

IMCAInternational Marine Contractors AssociationIMCA SF 20/20

High potential incident: gantry hoist failure

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

A gantry hoist failed while lifting palletised provisions onto a vessel, dropping cargo and a chain box onto the deck without injury. Previously unidentified internal corrosion caused securing bolts to fail. The flash describes changes to procurement, mechanical lifting procedures and maintenance and inspection record management.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 20/20
Date
6 July 2020
Topic
Corrosion, Dropped Objects, Mechanical Failure
Activity
Inspection and Maintenance, Lifting Operations
Control
Operating and Work Procedures
Sector
Marine Industry
Setting
Vessel
Link
Checked , working
Record
imca-sf-20-20-high-potential-incident-gantry-hoist-failure · added 1 September 2026