Safety Flash

Getting fall arrest equipment right

IMCAInternational Marine Contractors AssociationIMCA SF 21/23

Getting fall arrest equipment right

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

A crew member replacing mast lamp bulbs around 4 m above a vessel’s deck wore fall arrest equipment under a permit to work. The assessment overlooked equipment length and the lanyard’s minimum 6 m clearance marking. No fall or injury occurred; the flash stresses correct fall arrest calculations.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 21/23
Date
29 August 2023
Topic
Falls from Height
Activity
Inspection and Maintenance, Working at Height
Equipment
Fall Protection Equipment
Control
Permit to Work, Risk Assessment
Sector
Marine Industry
Setting
Vessel
Link
Checked , working
Record
imca-sf-21-23-getting-fall-arrest-equipment-right · added 1 September 2026