Safety Flash

NTSB: diesel generator engine failure

IMCAInternational Marine Contractors AssociationIMCA SF 24/24

NTSB: diesel generator engine failure

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

An offshore supply vessel suffered diesel generator failure and an engine-room fire during post-maintenance sea trials. An incorrectly sized replacement main bearing reduced lubrication pressure to adjacent connecting rod bearings. Effective crew firefighting limited the spread. The flash stresses identifying and documenting removed component part numbers to support correct replacement selection.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 24/24
Date
17 December 2024
Topic
Fire, Mechanical Failure
Activity
Inspection and Maintenance
Equipment
Rotating Machinery
Control
Emergency Response, Fire Protection
Sector
Marine Industry
Setting
Vessel
Link
Checked , working
Record
imca-sf-24-24-ntsb-diesel-generator-engine-failure · added 1 September 2026