Safety Flash

High potential DROPS near miss: Failed crane component

IMCAInternational Marine Contractors AssociationIMCA SF 26/20

High potential DROPS near miss: Failed crane component

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

A crane’s man-riding brake casing failed during preparation, dropping components to the deck without injury. Investigation identified hydraulic overpressure and incorrectly set relief valves, with commissioning changes insufficiently evaluated. The flash describes isolation by blanking and recommends valve adjustment checks and reviews of change management, commissioning, competence and maintenance procedures.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 26/20
Date
4 September 2020
Topic
Dropped Objects, Mechanical Failure, Pressure Systems
Activity
Inspection and Maintenance
Equipment
Crane, Valve
Control
Energy and Process Isolation, Management of Change, Operating and Work Procedures, Pressure Relief
Link
Checked , working
Record
imca-sf-26-20-high-potential-drops-near-miss-failed-crane-component · added 1 September 2026