Investigation Report

Electrical failure and subsequent grounding of feeder container vessel Clonlee

MAIBMarine Accident Investigation Branch

Electrical failure and subsequent grounding of feeder container vessel Clonlee

Read at MAIBOpens the publisher’s page on gov.uk

Summary

Investigation of Clonlee’s electrical blackout and grounding at the Port of Tyne on 16 March 2011. An intermittent electrical fault was considered most likely, but the exact cause remained undetermined. Analysis examines generator changeover, protection testing, maintenance, passage planning, bridge resources, emergency communications and company safety management.

Topics

About This Record
Publisher
Marine Accident Investigation Branch
Type
Investigation Report
Date
March 2012 (added from another catalogue record)
Topic
Electrical Safety, Human Factors, Vessel Grounding
Activity
Inspection and Maintenance, Navigation
Equipment
Navigation and Positioning Equipment, Rotating Machinery, Switchgear
Control
Emergency Response, Functional Testing, Operating and Work Procedures, Preventive Maintenance
Sector
Marine Industry
Setting
Port and Quayside, Vessel