Investigation Report

Coolant-Soaked Exhaust Heat Blankets Ignited on Spar Platform

BSEEBureau of Safety and Environmental Enforcement

04-29-2017 01:12 G22987 GC 680 Fire - Required Muster

Read at BSEEOpens the document on bsee.gov

Summary

Investigation of a fire on the Constitution spar platform on 29 April 2017. Compressor vibration wore a hole in coolant tubing against a retaining bolt, releasing coolant onto exhaust heat blankets. Saturated blankets ignited. Operators shut in the platform, extinguished the fire and mustered personnel; no reportable injuries occurred.

Topics

About This Record
Original title
04-29-2017 01:12 G22987 GC 680 Fire - Required Muster
Publisher
Bureau of Safety and Environmental Enforcement
Type
Investigation Report
Date
Unknown
Topic
Fire, Loss of Containment, Mechanical Failure
Equipment
Process Pipework and Pipelines
Control
Emergency Response, Fire Protection
Sector
Upstream Oil and Gas
Setting
Offshore Installation
Link
Checked , working
Record
bsee-8049463231 · added 2 October 2026