Safety Alert

BSEE Safety Alert 499 - Failed Umbilical Termination Results in Dropped Remotely Operated Vehicle (ROV)

BSEEBureau of Safety and Environmental EnforcementSafety Alert 499

BSEE Safety Alert 499 - Failed Umbilical Termination Results in Dropped Remotely Operated Vehicle (ROV)

Read at BSEEOpens the document on bsee.gov

Summary

An ROV dropped to the seafloor during recovery when its umbilical termination failed at a cursor transition point. Faulty resin and improperly positioned armoured strands were identified despite a previous successful pull test. BSEE recommends termination inspection procedures, training and pre-job connection checks. No personnel harm or seabed asset damage occurred.

Topics

About This Record
Publisher
Bureau of Safety and Environmental Enforcement
Type
Safety Alert
Reference
Safety Alert 499
Date
4 April 2025 (added from another catalogue record)
Topic
Dropped Objects, Mechanical Failure
Activity
Inspection and Maintenance, ROV Operations
Equipment
Remotely Operated Vehicle
Control
Competence and Training, Operating and Work Procedures, Pre-Use Checks
Sector
Upstream Oil and Gas
Setting
Vessel
Link
Checked , working