Safety Flash

BSEE: Umbilical termination failure leads to dropped ROV

IMCAInternational Marine Contractors AssociationIMCA SF 11/25

BSEE: Umbilical termination failure leads to dropped ROV

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

An ROV dropped to the seafloor during recovery when its umbilical parted at the cursor rail transition. Faulty resin casing and improperly arranged armoured strands compromised the attachment despite a previous successful pull test. BSEE recommends termination inspection procedures, re-termination training and pre-job connection checks. No personnel harm or seabed asset damage occurred.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 11/25
Date
18 June 2025
Topic
Dropped Objects, Mechanical Failure
Activity
Inspection and Maintenance, ROV Operations
Equipment
Remotely Operated Vehicle
Control
Competence and Training, Operating and Work Procedures, Pre-Use Checks
Setting
Vessel
Link
Checked , working
Record
imca-sf-11-25-bsee-umbilical-termination-failure-leads-to-dropped-rov · added 1 September 2026