Summary
This alert describes multiple incidents involving loss of integrity in LMRP H-4 connector bolts. It outlines BSEE directions to affected operators to suspend operations pending bolt replacement or recertification, with independent certification requirements. It also reports at least one similar failure outside the US Gulf of Mexico.
Classifications: Mechanical failure; equipment failure.
Classifications: Structural and asset integrity; asset integrity; structural integrity.
Classifications: Inspection and maintenance; asset inspection; equipment maintenance.
Classifications: Independent audit and verification.