Safety Flash

Corrosion cracking of strain-hardened type 304 stainless steel bolts

IMCAInternational Marine Contractors AssociationIMCA SF 10/18

Corrosion cracking of strain-hardened type 304 stainless steel bolts

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

This flash describes stainless-steel bolt failure during pneumatic leak testing of offshore gas pipework, attributed to chloride-induced stress corrosion cracking at temperatures below 50°C. It explains strain-hardening susceptibility and recommends considering desktop identification, visual surveys, prioritised replacement and disposal of stored Type 304/304L fasteners.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 10/18
Date
9 May 2018
Topic
Corrosion, Mechanical Failure, Pressure Systems, Structural and Asset Integrity
Activity
Inspection and Maintenance, Pressure Testing
Equipment
Process Pipework and Pipelines
Sector
Upstream Oil and Gas
Setting
Offshore Installation