Safety Flash

Chain hoist paid out unsupervised near running main engine

IMCAInternational Marine Contractors AssociationIMCA SF 01/24

Chain hoist paid out unsupervised near running main engine

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

An unattended electric chain hoist aboard a vessel paid out onto a running main engine near the generator drive shaft. A defective pendant button issued a continuous payout command. The flash examines operator assumptions, unsecured stowage and the unused emergency stop, and recommends checks, isolation review and maintenance review.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 01/24
Date
9 January 2024
Topic
Mechanical Failure
Activity
Inspection and Maintenance, Lifting Operations
Equipment
Operator Displays and Control Interfaces, Rotating Machinery
Control
Competence and Training, Energy and Process Isolation, Positive Retention and Reliable Securing, Pre-Use Checks
Sector
Marine Industry
Setting
Vessel
Link
Checked , working
Record
imca-sf-01-24-chain-hoist-paid-out-unsupervised-near-running-main-engine · added 1 September 2026