Safety Flash

Structural failure of a transponder housing

IMCAInternational Marine Contractors AssociationIMCA SF 01/99

Structural failure of a transponder housing

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

A transponder end blew off during storage in an onshore workshop. Seawater ingress during subsea operation reacted with battery electrolyte, generating gas whose pressure failed the plastic retaining ring. The vent bleed valve was closed. Recommendations include fitting a suitable vent valve where practicable, cautious opening and venting before shipment.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 01/99
Date
1 January 1999
Topic
Mechanical Failure, Pressure Systems
Equipment
Valve
Control
Pressure Relief
Setting
Onshore Facility
Link
Checked , working
Record
imca-sf-01-99-structural-failure-of-a-transponder-housing · added 1 September 2026