Safety Flash

LTI: diver injured during water jetting operations

IMCAInternational Marine Contractors AssociationIMCA SF 15/18

LTI: diver injured during water jetting operations

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

A saturation diver sustained a left-arm lost-time injury during subsea high-pressure water jetting when the gun failed and a component detached. The flash identifies loose locking bolts, inadequate nut retention, unavailable manuals and maintenance shortcomings. Actions included management of change, equipment-condition checks and a dive-team awareness briefing.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 15/18
Date
20 July 2018
Topic
Mechanical Failure, Pressure Systems
Activity
Inspection and Maintenance, Saturation Diving
Equipment
Hand Tools
Control
Management of Change, Positive Retention and Reliable Securing, Preventive Maintenance, Safety Communication
Setting
Subsea
Link
Checked , working
Record
imca-sf-15-18-lti-diver-injured-during-water-jetting-operations · added 1 September 2026