Safety Flash

Failure of chamber door spindles and seals

IMCAInternational Marine Contractors AssociationIMCA SF 07/07

Failure of chamber door spindles and seals

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

Two successive leaks at chamber-door spindle seals interrupted pressurisation on a diving support vessel following maintenance. Inspection found almost 70% of spindles unserviceable through sealing-area surface damage or bent shafts. The flash recommends identifying spindles and seals as critical components and including their inspection and replacement in planned maintenance.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 07/07
Date
14 August 2007
Topic
Mechanical Failure, Pressure Systems
Activity
Inspection and Maintenance, Saturation Diving
Equipment
Pressure Vessel
Control
Preventive Maintenance
Sector
Marine Industry
Setting
Vessel