Safety Flash

Diving bell TUP O-ring seal damage

IMCAInternational Marine Contractors AssociationIMCA SF 09/17

Diving bell TUP O-ring seal damage

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

A displaced O-ring obstructed diving bell mating on a DSV and was damaged during repeated clamp closures. Trunking pressurisation revealed leakage, prompting inspection and seal replacement. The flash identifies incomplete inspection and difficult access, recommending flange and seal checks between every bell run and describing improved access and inspection recording.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 09/17
Date
3 May 2017
Topic
Mechanical Failure, Pressure Systems
Activity
Inspection and Maintenance, Saturation Diving
Equipment
Diving Bell
Control
Operating and Work Procedures, Pre-Use Checks
Sector
Marine Industry
Setting
Vessel
Link
Checked , working
Record
imca-sf-09-17-diving-bell-tup-o-ring-seal-damage · added 1 September 2026