Safety Alert

Safety Alert 15 - Electrical Cable Testing

BSEEBureau of Safety and Environmental EnforcementBSEE Safety Alert 15

Safety Alert 15 - Electrical Cable Testing

Read at BSEEOpens the publisher’s page on bsee.gov

Summary

A Pacific OCS platform fire followed insulation testing of a submersible pump power cable when grounding produced a spark that ignited escaping well-annulus gas. The alert recommends avoiding rig-floor testing, using purged rooms where feasible, requiring permits and continuous flammable-gas monitoring in non-purged environments, and reducing sparking through suitable instruments and capacitance discharge.

Topics

About This Record
Publisher
Bureau of Safety and Environmental Enforcement
Type
Safety Alert
Reference
BSEE Safety Alert 15
Date
25 January 2000 (added from another catalogue record)
Topic
Electrical Safety, Fire, Hydrocarbon Release
Activity
Electrical Work, Inspection and Maintenance
Control
Atmospheric Gas Testing, Ignition Source Control, Permit to Work
Sector
Upstream Oil and Gas
Setting
Offshore Installation