Dropped object – Steel deck plate falls from pipelay tower
Read at IMCAOpens the publisher’s page on imca-int.com
Summary
A steel deck plate fell 9 m during pipelay tower inspection on a vessel in dry dock. Corroded, incorrectly specified bolts and inadequate support were identified in an undocumented modification. Nobody was hurt; barriers protected the drop zone. The flash recommends routine inspection of elevated plates and fixings, and controlled equipment modifications.